1.SC Codes
352
Error Name/Error Condition/Major Cause/Solution
Ring Binder: Device connection order error
The ring binder did not detect the fixed device connection information command
at the initial communication.
The interface cable connector disconnected/broken
Board on the ring binder or a downstream device defective
Replace the interface cable
Reconnect the connector
Replace the board on the ring binder or a downstream device
Error Name/Error Condition/Major Cause/Solution
Ring Binder: Junction gate abnormal
Junction gate failed to move out of the home position within the prescribed
time (400 pulses). The first occurrence triggers a jam, the second an SC
code.
The sensor could not detect the junction gate within the prescribed time (600
pulses). The first occurrence triggers a jam, the second an SC code.
Path JG motor (M201) defective
Motor overloaded
Connector loose, broken, defective
JG HP sensor (S203) defective
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
Error Name/Error Condition/Major Cause/Solution
Ring Binder: Pre-punch side fence HP error
Thee sensor failed to detect that the component had moved out of the home
position within the prescribed time (400 pulses). The first occurrence triggers
a jam, the second an SC code.
The sensor could not detect the component within the prescribed time (600
pulses). The first occurrence triggers a jam, the second an SC code.
Side jogger motor (M302) defective
Motor overloaded
Connector loose, broken, defective
Pre-punch jogger HP sensor (S302) defective