1.SC Codes
367
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
PSU defective
PCB defective
Reconnect the connector.
Replace the PSU Cooling Fan 1 on the LCT2.
Replace the harness
Replace the PSU.
Replace the PCB.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC781-
06
B
LCT2: PSU Cooling Fan 2 error
Cooling fan alarm “H (error)” is detected while the PSU Cooling Fan 2 on the
LCT2 is ON.
PSU Cooling Fan 2 on the LCT2 defective
Connector disconnected
Harness broken
PSU defective
PCB defective
Reconnect the connector.
Replace the PSU Cooling Fan 1 on the LCT2.
Replace the harness
Replace the PSU.
Replace the PCB
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC781-
07
B
LCT2: Bridge Unit Cooling Fan error
Cooling fan alarm “H (error)” is detected while the cooling fan on the bridge unit
of LCT2 is ON.
Cooling fan defective
Connector disconnected
Harness broken
PCB on the LCT2 defective
Reconnect the connector.
Replace the cooling fan.
Replace the harness
Replace the PCB on the LCT2.