1.1 Technical Parameter
Model
RD6012P
RD6012P-W
Input voltage range
7-70.00V
Output voltage range
0-60.000V
Output current range
0-12.000A
Output power range
0-720.00W
Input voltage measurement resolution
0.01V
Output voltage setting measurement resolution
0.001V
Output current setting measurement resolution
0.0001A(6A range) /0.001A(12A range)
Battery voltage measurement resolution
0.01V
Input voltage measurement accuracy
±(1%+5 digits)
Output voltage accuracy between setting and
measurement
±(0.5‰+4 digits)
Output current accuracy between setting and
measurement
±(1‰+6 digits)
Battery voltage measurement accuracy
±(0.5%+3 digits)
Automatic cut off current value when charging
Set by yourself
Output ripple typical
20mV VPP
Working temperature range
-10~40
External sensor Temperature detection range:
-10~100/0~200
External sensor Temperature detection accuracy:
±3/±6
Constant voltage mode response time
2ms
0.1A-5A load
Constant voltage mode load regulation
±(0.1%+2 digits)
Constant current mode load regulation
±(0.1%+3 digits)
Capacity measurement range
0-9999.99Ah
Energy measurement range
0-9999.99Wh
Constant voltage mode response time
±2
Max output voltage
input voltage÷1.1
-2
Cooling fan start condition
Output current>4A or
System temperature>50