TECHNICAL ASSISTANCE CENTRE
62
PARAMETERS MENU
The parameters menu for control of the ALU PRO power is divided into three sections:
- User Menu
- Installer Menu
- OEM Menu
User Menu
To access the User Menu parameters, press the “up arrow and down arrow” keys at the same time for two seconds;
the number of the selected parameter will appear in the top right (small digits) and its value in the middle (large digits).
To move forward through the parameters press the “up arrow” or “down arrow” keys and to change the value of the
parameter press the “+” or “–“ keys.
To exit the menu press the “i” or “mode” keys.
Code Description Minimum Maximum Default
P1 Clock adjustment – Hours:Minutes 00:00 23:59 -
P2 Calendar adjustment – Day.Month 1,01 31,12 -
P3 Calendar adjustment – Year 2000 2099 -
P4 Calendar adjustment – Day of the week [Mo | Tu | We | Th | Fr | Sa | Su] -
P5
Date when to change from daylight saving to sum-
mer time – Day.Month
1.01 31.12 25.03
P6
Date when to change from daylight saving to sum-
mer time – Day.Month
1.01 31.12 25.10
P900 CH scheduling – Pre-selection day
[MoSu | Mo | Tu | We | Th | Fr | Sa | Su |
MoFr | SaSu]
-
P901 CH scheduling – Start phase 1 00:00 P902 6:00
P902 CH scheduling – End phase 1 P901 P903 22:00
P903 CH scheduling – Start phase 2 P902 P903 23:59
P904 CH scheduling – End phase 2 P903 P905 23:59
P905 CH scheduling – Start phase 3 P904 P906 23:59
P906 CH scheduling – End phase 3 P905 23:59 23:59
P916 CH scheduling– Loading default values [No | Yes] NO
P960 DHW scheduling – Pre-selection day
[MoSu | Mo | Tu | We | Th | Fr | Sa | Su |
MoFr | SaSu]
-
P961 DHW scheduling – Start phase 1 00:00 P902 6:00
P962 DHW scheduling – End phase 1 P901 P903 22:00
P963 DHW scheduling – Start phase 2 P902 P903 23:59
P964 DHW scheduling – End phase 2 P903 P905 23:59
P965 DHW scheduling – Start phase 3 P904 P906 23:59
P966 DHW scheduling – End phase 3 P905 23:59 23:59
P976 DHW scheduling – Loading default values [No | Yes] NO