Model RLS 200/E
RBNA Code C9355400 C9355410
Control circuit power supply V/Ph/Hz 120/1/60
Main power supply (+/- 10%) V/Ph/Hz 230/3/60 460/3/60
Fan motor IE2/EPACT rpm
HP
V
A
3500
7.5
230
17.8
3500
7.5
460
8.9
Pump motor IE2/EPACT rpm
HP
V
A
3530
1
230
3
3530
1
460
1.5
Ignition transformer Oil V1 - V2
I1 - I2
120 V - 2 x 5 kV
2.7 A - 30 mA
Gas V1 - V2
I1 - I2
120 V - 1 x 8 kV
1.6 A - 20 mA
Electrical power consumption W 7000 7000
Electrical control circuit consumption W max 750
Total electrical consumption W 7750 7750
Electrical protection NEMA 1
Model Code Code RBNA Voltage Flame safeguard
RLS 160/E
20113149
C9354400 230/3/60
Burner mountedC9354410 460/3/60
20023415 C9354401 575/3/60
RLS 200/E 20127086
C9355400 230/3/60
Burner mounted
C9355410 460/3/60
inch A B C lbs
RLS 160/E 59
1
/
16”
33
43
/
64”
39
3
/
8”
210
RLS 200/E 59
1
/
16”
33
43
/
64”
39
3
/
8”
210