20106891
26
GB
Installation
Tab. L
MBtu/hr ( GCV )
Nozzle
Supply
Pressure
High Fire Low Fire
Type GPH kg/h PSI By-pass
Pressure
Flow rate
GPH
By-pass
Pressure
Flow rate
GPH
RLS510
5.000
Fluidics N2 & N4
45° - 60°)
125
300
268 35,7 100 8,6
6.500 175 253 46,4 100 13,4
7.500 200 253 53,6 100 14,7
8.500 200 267 60,7 100 14,7
9.500 225 268 67,9 100 15,0
10.500 275 263 75,0 100 18,6
11.500 300 258 82,1 100 20,8
12.500 325 258 89,3 100 21,8
13.500 350 255 96,4 100 23,4
14.500 350 261 103,6 100 23,4
15.500 375 255 110,7 100 29,5
16.500 400 236 117,9 100 35,2
17.500 450 261 125,0 100 36,8
18.500 500 253 132,1 100 38,1
19.500 500 260 139,3 100 38,1
19.200 525 253 137.1 100 39,1