RIGOL     DG1000 Command System                                
          
 Programming Guide for DG1000 
DC offset) selected by the 
command via CH1.  
Explanations    If the parameters you set are less than three, the sequence 
would be: <frequency>, <amplitude>, <offset>.  
  The default units of <frequency>, <amplitude> and <offset> 
are Hz, Vpp and V
 respectively. 
Example
APPL:USER 1000,5.0,-1.5 
 
8.
APPLy? 
Syntax  APPLy? 
Function   Query the current configuration 
of CH1 and the type of wave 
outputted. 
Return Value  The query returns a character string enclosed in double quotation 
marks, including function, frequency, amplitude and offset. Such as, 
CH1:"SIN,1.000000e+03,5.000000e+00,-1.500000e+00" 
 
9.
APPLy:SINusoid:CH2 
Syntax
APPLy:SINusoid:CH2 [<frequency>[,<amplitude>[,<offset>]]] 
Function   Generate a sine wave with specific frequency, amplitude and DC 
offset via CH2.  
Explanations    If the parameters you set are less than three, the sequence 
would be: <frequency>, <amplitude>, <offset>.  
  The default units of <frequency>, <amplitude> and <offset> 
are Hz, Vpp and V
DC
 respectively. 
Example  APPL:SIN:CH2 1000,5.0,-1 
 
10.
APPLy:SQUare:CH2 
Syntax
APPLy:SQUare:CH2 [<frequency>[,<amplitude>[,<offset>]]] 
Function   Generate a square wave with specific frequency, amplitude and DC 
offset via CH2. This command would overwrite the current duty cycle 
setting and select 50% automatically.  
Explanations    If the parameters you set are less than three, the sequence 
would be: <frequency>, <amplitude>, <offset>.  
  The default units of <frequency>, <amplitude> and <offset> 
are Hz, Vpp and V
 respectively. 
Example
APPL:SQU:CH2 1000,5.0,-1 
11.