DG1000 Command System         RIGOL 
Programming Guide for DG1000 
offset via CH1.  
Explanations    If the parameters you set are less than three, the sequence 
would be: <frequency>, <amplitude>, <offset>.  
  The default units of <frequency>, <amplitude> and <offset> 
are Hz, Vpp and V
 respectively. 
Example
APPL:PULS 1000,5.0,-1.5 
 
5.
APPLy:NOISe 
Syntax  APPLy:NOISe [<frequency |DEFault>[,<amplitude>[,<offset>]]] 
Function   Generate a Gaussian noise with specific amplitude and DC offset via 
CH1.  
Explanations    Although the frequency parameter makes no impression on this 
command, a value or “DEFault” must be specified. (noise 
function has a 5MHz bandwidth) 
  If the parameters you set are less than three, the sequence 
would be: <frequency>, <amplitude>, <offset>.  
  The default units of <frequency>, <amplitude> and <offset> 
are Hz, Vpp and V
DC
 respectively.  
Example
APPL:NOIS DEF,5.0,2.0 
 
6.
APPLy:DC 
Syntax  APPLy:DC [<frequency|DEFault>[,<amplitude>|DEFault>[,< 
offset>]]]  
Function   Generate a DC signal with electrical level specified by < offset > via 
CH1.  
Explanations    Although the frequency and amplitude parameters make no 
impression on this command, a value or “DEFault” must be 
specified. 
  If the parameters you set are less than three, the sequence 
would be: <frequency>, <amplitude>, <offset>.  
  The default units of <frequency>, <amplitude> and <offset> 
are Hz, Vpp and V
 respectively. 
Example
APPL:DC DEF,DEF,-2.5 
 
7.
APPLy:USER 
Syntax
APPLy:USER [<frequency>[,<amplitude>[,<offset>]]] 
Function 
Generate an arbitrary wave (with specific