  You can also send the :COUPling[<n>]:FREQuency:MODE command to set and query the frequency 
coupling mode. 
 
Return Format 
The query returns OFFS or RAT. 
 
Example 
:FREQ:COUP:MODE OFFS    /*Sets the frequency coupling mode of CH1 to Frequency Deviation.*/ 
:FREQ:COUP:MODE?        /*Queries the frequency coupling mode and the query returns OFFS.*/ 
 
 
[:SOURce[<n>]]:FREQuency:COUPle:OFFSet 
 
Syntax 
[:SOURce[<n>]]:FREQuency:COUPle:OFFSet <frequency> 
[:SOURce[<n>]]:FREQuency:COUPle:OFFSet? 
 
Description 
Sets the frequency deviation in the frequency coupling. 
Queries the frequency deviation in the frequency coupling. 
 
Parameter 
-99.999 999 999 9 MHz to 99.999 999 999 9 MHz 
 
Remarks   
  Select the desired frequency coupling mode (
[:SOURce[<n>]]:FREQuency:COUPle:MODE) and set the 
corresponding frequency deviation or frequency ratio (
[:SOURce[<n>]]:FREQuency:COUPle:RATio) 
before enabling the frequency coupling function (
[:SOURce[<n>]]:FREQuency:COUPle[:STATe]). You 
cannot set the frequency coupling mode and frequency deviation/ratio after the frequency coupling 
function is enabled. 
  When the frequency coupling function is disabled, if the current frequency coupling mode is frequency 
deviation, sending this command can set the frequency deviation; if the current frequency coupling 
mode is frequency ratio, sending this command can set the frequency coupling mode to frequency 
deviation and set the frequency deviation. 
  You can also send the 
:COUPling[<n>]:FREQuency:DEViation command to set and query the 
frequency deviation in the frequency coupling of the specified channel. 
 
Return Format 
The query returns the frequency deviation in scientific notation, with 7 effective digits. For example, 
1.000000E+02 (the frequency deviation in the frequency coupling is 100 Hz). 
 
Example 
:FREQ:COUP:OFFS 100    /*Sets the frequency deviation in the frequency coupling to 100 Hz.*/ 
:COUP1:FREQ:DEV?        /*Queries the frequency deviation in the frequency coupling and the query 
returns 1.000000E+02.*/ 
 
 
[:SOURce[<n>]]:FREQuency:COUPle:RATio 
 
Syntax   
[:SOURce[<n>]]:FREQuency:COUPle:RATio <ratio> 
[:SOURce[<n>]]:FREQuency:COUPle:RATio? 
 
Description   
Sets the frequency ratio in the frequency coupling.