EasyManua.ls Logo

Rigol DS1000B Series

Rigol DS1000B Series
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RIGOL Command Systems
Programming Guide for DS1000B Series
VIDEO Trigger
1. :TRIGger:VIDEO:MODE
Command Format:
:TRIGger:VIDEO:MODE <mode>
:TRIGger:VIDEO:MODE?
Function:
The command sets the trigger sync mode as ODDfield, EVENfield, LINE or
ALLlines.
Returned Format:
The query returns ODD FIELD, EVEN FIELD, LINE or ALL LINES.
Example:
:TRIG:VIDEO:MODE EVEN Set the trigger sync mode as even field.
:TRIG:VIDEO:MODE? Return EVEN FIELD.
2. :TRIGger:VIDEO:POLarity
Command Format:
:TRIGger:VIDEO:POLarity {POSitive|NEGative}
:TRIGger:VIDEO:POLarity?
Function:
The command sets the video polarity as POSitive (it is applicable for the video
signal that the black level is low) or NEGative (the black level is high).
Returned Format:
The query returns POSITIVE or NEGATIVE.
Example:
:TRIG:VIDEO:POL POS Set the video polarity as positive.
:TRIG:VIDEO:POL? Return POSITIVE.

Other manuals for Rigol DS1000B Series

Related product manuals