Continuous ow internal ueing guide: 11748-D 04-13 | 11
Roof cowl for vertical installations (FFSSROOFCOWL)
953 ± 5 mm
483 ± 5 mm
Black powder coat
cast aluminium
Black PVC plastic
White PVC plastic
Can be cut to size.
Includes two black injection UV roof protectors
for covering and protecting the white flue pipe
from UV damage. Also includes a flue pipe clamp
(pictured below) to support the flue.
Inner = 80 mm
Outer = 125 mm
Stainless steel inner protrudes from base of roof
cowl by approx. 10 mm
Direct flue kit for horizontal installations (FFSSKIT)
Flue pipe (FFSSPIPE1000)
Can be cut to size.
Includes a Munzing ring (not pictured) to support
the flue.
Dimensions:
Inner = 80 mm
Outer = 125 mm
End to end dimension = approx. 778 ± 10 mm
Wall trim to wall trim = approx. 480 ± 5 mm
Terminal centre to base = approx. 120 ± 5 mm
Terminal protrudes approximately 150 mm from the
wall.
UP
97 5
515
12 5
80
85
Can be cut to size.
Includes a Munzing ring to support the flue.