TEMPERATURE CONTROLS—PROGRAMMING
Q: Are Four temperature controllers fitted?
If Yes.
You will need to activate the fourth controller.
STEP 1: For the Primary controller only press and hold the ‘Transfer’ and ‘On/Off’
buttons simultaneously (see fig 2.) until a “beep” is heard (approx. 5 seconds)
STEP 2: Check that the display on all Four controllers is lit and
displaying a temperature when switched on. If any ONE of the
controllers displays two dashes (see fig 1.) in the display repeat
STEP 1.
This completes the activation procedure for this configuration.
If No. (You have three or less controllers)
You will need to program the primary controller to enable the selection of temperatures
higher than 50ºC.
STEP 1: For the Primary controller only press and hold the ‘Transfer’ and ‘On/Off’
buttons simultaneously (see fig 2.) until a “beep” is heard (approx. 5 seconds)
STEP 2: When the Primary controller is switched on it should be possible to select
temperatures higher than 50ºC. If not repeat STEP 1.
Note:
If the primary controller is replaced, repeat STEP 1 above for the new controller.