Neo operation guide: 11907-E 05-14 | 19
Abnormal ame pattern
Each Rinnai Flame Fire has a distinct flame pattern. This should look the same every
time you start your fire, after an initial warm up period of approximately 20 minutes.
Abnormal flame performance and/or pattern can indicate a problem with your fire, such as
blocked gas injectors, or that the log set (burn media) has shifted from when the fire was first
installed. There are some warning signs that could indicate a problem.
- Unusual smell from the appliance
- Continued difficulty or delay in establishing a
flame
- Flame appears either very short or very long
- Flame only burns part way across the burner
- Severe soot building up on the inside of the glass
If any of the above signs occur, please call Rinnai to
discuss.
Normal flame paern
Abnormal flame paern
Soot build up