36 KBP Series Manual
PVC/CPVC Equivalent Vent Length Calculaon Sheet
Note: Ensure SW 1 in DIPSW 1 is in “OFF” posion if vent length is greater than 21 (6.4m).
Fing / Terminaon Type Number of Equivalent Vent Total Equivalent
1) 90 elbow
x
5
=
2) 45 elbow
x
2.5
=
3) IPEX Low Prole Terminaon
X
5
=
4) IPEX 4" Concentric Terminaon
x
20
=
5) IPEX 3" Concentric Terminaon
x
20
=
6)
3" Tee Terminaon
x
5
=
7)
4" Tee Terminaon
x
5
=
8) 3" Snorkel Terminaon
x
15
=
9) 4" Snorkel Terminaon
x
15
=
10) Length of Straight Secon in feet NA
=
Total (add up
lines 1 through
Equivalent Vent Length Calculaon Sheet