Rinnai RUR98i - The Installation Must Conform with Local Codes or; In the Absence of Local Codes, with the National; Fuel Gas Code, ANSI Z223.1;NFPA 54, or the Natural Gas and Propane Installation Code, CSA; B149.1. if Installed in a Manufactured Home, the Installation Must Conform with the Manufactured

Rinnai RUR98i
160 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
KBP Series Manual 51

Ensure that hot and cold water lines are not
crossed to the unit and are leak free.
A manual gas control valve has been placed in the
gas line to the water heater.
Ensure that a pressure relief valve is installed with
a rang that exceeds the BTU input of the water
heater model. Refer to the rang plate on the
side of the water heater for BTU input.
Clean the inlet water lter(s) by closing the cold
and hot water inlet isolaon (shut-o) valves. Put
a bucket under the lter(s) at the boom of the
water heater to catch any water that is contained
inside the unit. Unscrew the water lter(s) .
Rinse the lter(s) to remove any debris. Install
the lter(s) and open the isolaon valves.
If installed in an applicaon using thermal by-pass
valve, remember to remove plug and replace with
the supplied lter (located within the unit). 
discard the plug. Plug is to be retained
should the applicaon be changed to a dedicated
return in the future.
Purge air from recirculaon line.
Check the gas lines and connecons for leaks.
Conrm that the gas inlet pressure is within limits.
Conrm that the water heater is rated for the gas
type supplied.
Conrm that the electricity is supplied from a 120
VAC, 60 Hz power source, is in a properly
grounded circuit, and turned on.
Verify the temperature controller is funconing
properly.
Verify that SW 2 and SW 3 in DIPSW 1 is set
correctly for your altude.
Ensure Dip Switch sengs are properly set for the
desired recirculaon mode.
Verify the system is funconing correctly by
connecng your manometer to the gas pressure
test port on the water heater. Operate all gas
appliances in the home or facility at high re. The
inlet gas pressure at the water heater must not
drop below that listed on the rang plate.
If the water heater is not needed for immediate
use, then drain the water from the heat
exchanger.
Install the front panel.
Explain to the customer the importance of not
blocking the vent terminaon or air intake.
Explain to the customer the operaon of the
water heater, safety guidelines, maintenance, and
warranty.
The installaon must conform with local codes or,
in the absence of local codes, with the Naonal
Fuel Gas Code, ANSI Z223.1/NFPA 54, or the
Natural Gas and Propane Installaon Code, CSA
B149.1. If installed in a manufactured home, the
installaon must conform with the Manufactured
Home Construcon and Safety Standard, Title 24
CFR, Part 3280 and/or CAN/SCA Z240 MH Series,
Mobile Homes.
Inform the consumer if the isolaon valves are
not installed or if a water soening system is not
installed.



