KCM Series Manual 13
Venng Guidelines

Do not use cellular core PVC/CPVC.
Do not use Radel, ABS, or galvanized material to
vent this appliance.
Do not cover non-metallic vent pipe and ngs
with thermal insulaon.
Do not combine vent components from dierent
manufacturers.
Vent diameter must not be reduced.
Do not connect the venng system with an
exisng vent or chimney.
Do not common vent.

This water heater is a direct vent water heater and
therefore is cered and listed with the vent
system. You must use vent components that are
cered and listed with the water heater model.
The vent system must vent directly to the outside
of the building and use outside air for combuson.
Avoid dips or sags in horizontal vent runs by
installing supports per the vent manufacturer’s
instrucons.
Support horizontal vent runs every four feet and
all vercal vent runs every six feet or in
accordance with local codes.
Venng should be as direct as possible with a
minimum number of pipe ngs.
Vent connecons must be rmly pressed together
so that the gaskets form an air ght seal.
The vent piece connected to the water heater
must be secured with one self-tapping screw.

Refer to the instrucons of the vent system
manufacturer for component assembly
instrucons.
If the vent system is to be enclosed, it is suggested
that the design of the enclosure permit inspecon
of the vent system. The design of such enclosure
shall be deemed acceptable by the installer or the
local inspector.

If it becomes necessary to access an enclosed vent
system for service or repairs, Rinnai is not responsible
for any costs or dicules in accessing the vent
system. The warranty does not cover obtaining
access to a vent system in an enclosed environment.

 
Concentric OFF
Twin Pipe ON

Prior to the installaon of the vent system, the dip
switches on the PCB board must be properly set for
the venng conguraon selected for the applicaon.
(Unit comes defaulted for concentric applicaons)

-
-



Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai RUS75e series and is the answer not in the manual?

Rinnai RUS75e series Specifications

General IconGeneral
BrandRinnai
ModelRUS75e series
CategoryWater Heater
LanguageEnglish

Related product manuals