54 KCM Series Manual
Check local codes for the maximum water
temperature seng allowed when used
in nursing homes, schools, day care
centers, and all other public applicaons.
If a newly installed unit with a controller
has not been powered for at least 6 hours
then the temperature will return to the
default seng of 120° F (49° C) if power is
interrupted.
There may be a variaon between the
temperature displayed on the
temperature controller and the
temperature at the tap due to weather
condions or the length of pipe to the
water heater.
1. If the water heater is o, press the
Power buon to turn on.
2. If the Priority light is o, then press
the “Priority buon” on the
temperature controller. The orange
Priority light will glow indicang that
this controller is controlling the
temperature and that the water
heater is ready to supply hot water.
(The priority can only be changed
while no hot water is running.)
3. Press the up or down buons to
obtain the desired temperature
seng.
All hot water sources are able to
provide water at this temperature
seng unl it is changed again at this
or another temperature controller.
The units referenced in this manual do not include a
temperature controller.
The MC-91-2 controller is the standard temperature
controller.
DO NOT repeatedly operate the water heater and then
use a hot water tap while the controller is turned o.
Operang the water heater in this way to alternately
produce hot water may cause water to condense on the
outside of internal parts and accumulate in the water
heater cabinet.
Dimensions (inches): 3.5 W x 4.75 H x 0.75 D
Temperature
Display
Priority
Indicator
Priority
Button
ON/OFF
Button
In Use
Indicator
Temperature
Selection
MC-91-2US
Temperature Opons Without a Temperature Controller
The default temperature seng for this appliance installed without a temperature controller is 120° F (49° C). If
desired, the temperature seng can be changed by adjustment of the dip switches:
DIPSW1
SW5 SW6
120° F OFF OFF
125° F ON OFF
135° F OFF ON
140° F ON ON
Fahrenheit °F 120 125 135 140
Celsius °C 49
52 57 60
Displayed As 1 2 3 4
Without a controller the status monitor (see page 56) will show the temperature as follows: