KCM Series Manual 43

Do not rely on the gas or water piping to ground the
water heater. A screw is provided in the juncon box
for the grounding connecon.
The water heater requires 120 VAC, 60 Hz power from
a properly grounded circuit.
If using the 5 foot long power cord, plug it into a
standard 3 prong 120 VAC, 60 Hz properly grounded
wall outlet.
On outdoor models, a disconnect switch must be
provided and installed for the incoming 120 VAC
power. It should be a type that is suitable for outdoor
use. Check the Naonal Electrical Code, ANSI/NFPA
70 and your local codes for a proper switch type to
use in your area.
The wiring diagram is located on the Technical Sheet
aached to the inside of the front cover.
WARNING
Do not use an extension cord or an adapter plug with
this appliance.
The water heater must be electrically grounded in
accordance with local codes and ordinances or, in the
absence of local codes, in accordance with the
Naonal Electrical Code, ANSI/NFPA No. 70.
Indoor water heaters are equipped with a three-
prong (grounding) plug for your protecon against
shock hazard and should be plugged directly into a
properly grounded three-prong receptacle. Do not
cut or remove the grounding terminal from this plug.


Set SW3 in DIPSW 1 to the values shown in table
below for your altude. The default seng for the
appliance is 0-2000  (0-610 m) with switches SW3 in
the OFF posion.
When the DIP switch is adjusted, it is not necessary to
adjust the gas pressure seng for high altude.
 
-- OFF
-- ON

A manual gas control valve is placed in the gas
line to the water heater.
Check the gas lines and connecons for leaks.
Conrm that the gas inlet pressure is within
limits.
Conrm that the water heater is rated for the gas
type supplied.
Conrm that the electricity is supplied from 120
VAC, 60 Hz power source and is in a properly
grounded circuit.
Conrm that an extension cord or an adapter plug
has been used with the water heater.

(indoor models only)
Adjust SW 1 in DIPSW 1 if required. Refer to the
secon “Maximum vent length”.
120V Wiring
Blue or Black wire: hot leg
Brown or White Wire: neutral
Cable Clamp
Remote Control
Cable
Cable
Clamp
Remote Control
Connecon Terminals
DIPSW 1
DIPSW 2
Ground
Screw
Status Monitor