46 KCM Series Manual

The water heater is not subject to corrosive
compounds in the air.
Water supply does not contain chemicals or
exceed total hardness referenced in manual.
Clearances from the water heater unit are met.
Clearances from vent terminaon are met.
For indoor models, ensure you have used the
correct venng products for the model installed
and that you have completely followed the
venng manufacturer’s installaon instrucons
and these installaon instrucons.
For indoor models, verify that the vent system
does not exceed the maximum length for the
number of elbows used.
For indoor models, verify that SW 1 in DIPSW 1
has been adjusted for vent length if necessary.
Refer to the secon on Maximum Vent Length.
For indoor models, ensure SW4 in DIPSW 2 is set
to the appropriate venng style.
Purge water line of all debris and air by closing
hot isolaon valve and opening the cold isolaon
valve and its drain. 
 Use a bucket or hose if necessary.
Ensure that hot and cold water lines are not
crossed to the unit and are leak free.
A manual gas control valve has been placed in the
gas line to the water heater.
Ensure a pressure relief valve is properly installed
with a rang that exceeds the BTU input of the
water heater model. Refer to the rang plate on
the side of the water heater for BTU input.
Clean the inlet water lter by closing the cold and
hot water inlet isolaon (shut-o) valves. Put a
bucket under the lter at the boom of the water
heater to catch any water that is contained inside
the unit. Unscrew the water lter. Rinse the lter
to remove any debris. Install the lter and open
the isolaon valves.
Check the gas lines and connecons for leaks.
Conrm that the gas inlet pressure is within
limits.
Conrm that the water heater is rated for the gas
type supplied.
Conrm that the electricity is supplied from a 120
VAC, 60 Hz power source, is in a properly
grounded circuit, and turned on.
Verify the temperature controller or status
monitor is funconing properly.
Verify that SW3 in DIPSW 1 is set correctly for
your altude.
Verify the system is funconing correctly by
connecng your manometer to the gas pressure
test port on the water heater. Operate all gas
appliances in the home or facility at high re. The
inlet gas pressure at the water heater must not
drop below that listed on the rang plate.
introduce toxic chemicals such as those
used for boiler water treatment to the potable
water used for space heang.
If the water heater is not needed for immediate
use, drain the water from the heat exchanger.
Install the front panel.
Explain to the customer the importance of not
blocking the vent terminaon or air intake.
Explain to the customer the operaon of the
water heater, safety guidelines, maintenance, and
warranty.
The installaon must conform with local codes or,
in the absence of local codes, with the Naonal
Fuel Gas Code, ANSI Z223.1/NFPA 54, or the
Natural Gas and Propane Installaon Code, CSA
B149.1. If installed in a manufactured home, the
installaon must conform with the Manufactured
Home Construcon and Safety Standard, Title 24
CFR, Part 3280 and/or CAN/SCA Z240 MH Series,
Mobile Homes.
Inform the consumer if the isolaon valves are
not installed or if a water soening system is not
installed.


