4. BASIC OPERATION
IMR02L04-E3
4-36
Continued from the previous page.
Name Symbol Data range
Factory set
value
DO9 to DO12
Energized/De-energized
EXDO3
0: Energized 1: De-energized
00000 Value at SV display
DO9
DO10
DO11
DO12
Unused
0000
Transmission output action in Reset
mode
R.AO
0: Action stop 1: Action continued
00000 Value at SV display
OUT2
OUT3
Unused
00
Event action in Reset mode
R.EV
0: Action stop 1: Action continued
00000 Value at SV display
Event 1
Event 2
Event 3
Event 4
HBA1 or HBA2
00000
Transmission output action at Pattern
end
P.ED.AO
0: Action stop 1: Action continued
00000 Value at SV display
OUT2
OUT3
Unused
Action of OUT1 stops or continues based on the setting of
Control action selection at Pattern end.
00
Event action at Pattern end
P.ED.EV
0: Action stop 1: Action continued
00000 Value at SV display
Event 1
Event 2
Event 3
Event 4
HBA1 or HBA2
00000
Function block 31 (F31.01)
OUT1 assignment
LOGC1
0: Manipulated output value 1 (MV1) [For Control output]
[PID control or Heat/Cool PID control: Heat-side output
Position proportioning PID control: Open-side output]
1: Output program value 1 [For Control output or
Transmission output (Voltage/Current output)]
0
Function block 32 (F32.01 to F32.03)
OUT2 assignment
LOGC2
Voltage output or Current outpu
t
Control output: 1, 2, 7
Transmission output: 3 to 7
0: None
1: Manipulated output value 1 (MV1) [Feedback
resistance (FBR) input value when FBR input is
specified with the Position proportioning PID control.]
2: Manipulated output value 2 (MV2) [Cool-side output
at Heat/Cool PID control]
3: Measured value (PV)
4: Deviation value (DEV)
5: Set value (SV) monitor
6: Segment time (percentage basis)
7: Output program value 2
Manipulated output value (MV1 or MV2) may be used as a
transmission output.
Relay contact output, Voltage pulse output, Triac output
or Open collector output
Control output: 21, 22, 23
Event output: 24 to 53
20: None
Heat/Cool PID
control:
22 or 2
(varies with
output type)
Position
proportioning
PID control:
22
Other control
method:
0 or 20
(varies with
output type)
When the
OUT2 is not
provided: 0
Continued on the next page.