Remote ON / OFF Functions
Set TT = OF in the Advanced Installer Menu
TheSMART2000canbeconnectedtoanexternaldrycontact,whenthiscontact
isclosedthethermostatwillturnOFF.SeeFigure23.Whenthethermostathas
beenswitchedOFFbytheTTterminalsthewordOFFwillashintheLCDto
indicate that this has been the shutdown method. The thermostat will return to
theusersengswhenthisswitchisOPEN.
Using the Occupancy Mode
Set TT = OC in the Advanced Installer Menu
TheSMART2000canalternatebetweentheuserpreferredsetpointsandan
installerpreprogrammedsetpointwhenrequired.Simplywirearemoteswitch
tothethermostatTTterminals.SeeFigure23.WhentheswitchisOPEN,the
usersengswillcontroltheroomtemperature,whentheswitchisCLOSEDthe
InstallerOC(OccupiedCoolingvalue)andOH(OccupiedHeangvalue)sengs
will be used to control the room temperature.