10
11 Troubleshooting
Symptom Probable Cause Action
No response
(The indicator not on)
No flushing
1. No batteries or wrongly installed (A35945E..0 ,
A35945S..0)
2. A/C power source outage or power cut
(A35945M..0 , A35945T..0)
3. There are sundries in front of a sensor The sensor
window is dirty.
4. The wire connection is not good or wrongly
connected.
1. Check the batteries
2. Check the power source
3. Check the sensor window
4. Check the wire connector
There is response
(The indicator flickers)
No flushing or bad flushing result
1. The installation is just finished.
2. The inlet valve is not fully opened.
1. Wait for 60 seconds
2. Fully open the inlet valve
Not enough water
1. The inlet valve is not opened.
2. The filter is blocked.
3. The water pressure is too low.
1. Fully open the inlet valve.
2. Clean the filter
3. Contact the water supplier
Water can’t stop
(The indicator not flickering)
There is dirt inside the solenoid
valve.
Clean the IR filter
No flushing but the indicator flickers
The batteries are run out
(A35945E..0 , A35945S..0)
Change the batteries
Other Please contact with the dealer for further service.