Pg
14
R9 V Instruction Manual_v12.indd 13
8/07/19 20:21
MACHINE INSTALLATION
CONNECTING TO MAIN WATER SUPPLY
The R9 V is preset at the factory to use the supplied 1.9 litre water reservoir.
To connect the R9 V machine to mains water supply, use the steel braided
water hose provided and ensure the following instructions are adhered to:
1.
Use a certified plumber to complete the installation and
ensure that the installation meets local authority standard and
regulations in all cases.
2.
Line pressure exceeding 4 bars should be limited with the use of a
pressure regulating valve on the water feed line.
3.
Use a shut off valve to isolate the water supply to the machine.
4.
If you are drawing water from a non pressurised system (ie. from a
remote water supply tank, not mains pressurised) fit a non return
valve to the end of the water supply hose to ensure that the line
pressure is maintained at all times.
5.
Use an in line filter to ensure the water supply of the machine
is of the highest quality - ask your plumber what he would
recommend.
6.
Once the mains installation is complete it will be necessary to
switch the machine from tank to water supply.
See page 20. Water source settings.