TECHNICAL DATA
Voltage: Please refer to the technical data plate on the machine
Wattage Please refer to the technical data plate on the machine
Temperature The machine should not be operated with temperatures under 6°C
and over 36 °C.
Water The machine must be operated with soft, clean drinking water. If the
local water supply has a has a high mineral content use a water
softener. A build up of mineral deposit may restrict the flow of water
within the hydraulic systems causing damage to the machine and
risking personal injury. Rocket Espresso recommends installation of
an in line filter.
Water pressure from the mains Maximum water inlet pressure is 6 Bar (0,6 MPa – 600 KPa). Please
install a pressure reducing valve if water pressure from the mains is
higher.
The minimum water pressure is 1.5 Bar (0.15MPa-1500 KPa)
Hydraulic connections Water inlet 3/8” gas
Machine ventilation Please make sure that there is an open area of at least 100 mm on
each side and behind the machine to allow adequate ventilation
Brew boiler capacity 1,9 litre/each (incl. neck and saturated group)
Service boiler capacity 2 group: 9,0 litre
Service boiler capacity 3/4 group: 12,0 litre