EasyManuals Logo

Rocket Espresso R9V Series User Manual

Rocket Espresso R9V Series
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #44 background imageLoading...
Page #44 background image
Pg
26
R9 V Instruction Manual_v12.indd 27
8/07/19 20:21
SETTING THE COFFEE VOLUME
PORTIONS (volumetric portion control)
A flow meter allows the machine to calculate the precise coffee volume you
would like from the single or double porta filter. (Generally 25 to 30ML from the
single porta filter and 50 to 60 ML from the double porta filter). When you are
sure the grind setting is correct you can set the flow meter.
It is important to understand that the volumetric portion control will differ
between each pressure profile. The flow meter will count total water volume
irrespective of the time it may take.
Example; Pump pressure of 9 bar over 30 seconds will yield a different total
volume than 5 bar over the same 30 seconds.
Screen 3 Programme symbol Programme mode screen
1.
Navigate to Screen 3 and press
symbol.
2.
Load a single portafilter and press the symbol.
3.
The extraction will begin. When you have 25-30ml (1 cup) of
espresso in the cup press cup symbol to stop the extraction.
4.
Press the Rocket Symbol to return to the home screen.
5.
Now, every time you press the one cup symbol on the home
screen you will get the exact amount you selected.
To program the double portafilter do the same process with
the
cup
(50-60ml).