Maintenance
Repair
MagneMover LITE Service Manual 117
Rockwell Automation Publication MMI-UM037A-EN-P - April 2020
12. Place the mounting holes on the vehicle over the array posts. Realign the shims if nec-
essary to make sure that they align with the vehicle.
13. Secure the array to the vehicle with the four M4 x 12 mm screws that were removed in
Step 4 and Loctite 243. Tighten each screw to 1.5 N•m [13 in•lb].
NOTE: The Loctite must cure for 2 hours at 22° C [72° F] before using the puck.
14. Replace the vehicle, see Replace Precision Rail Vehicles on page 104.
15. Restart the path.
16. Dispose of the removed magnet array appropriately.