Maintenance
Preventive Maintenance
38 MagneMotion
Rockwell Automation Publication MMI-UM037A-EN-P - April 2020
3. Initiate the IP65 washdown of compatible components (motors, switches) or material
in transport.
• Maximum water volume: 12.5 liters [0.26 gallons] per minute.
• Maximum pressure: 30 kN/m
2
[6.14 psf] at distance of 3 m [9.8 ft].
4. If only the motors, pucks, and magnet arrays are being cleaned, make sure that they are
dry and return the MagneMover LITE transport system to normal operation.