Maintenance
Preventive Maintenance
MagneMover LITE Service Manual 47
Rockwell Automation Publication MMI-UM037A-EN-P - April 2020
have applicators that are mounted in both locations on the same vehicle. The felt end
of the applicator is always pointed inwards toward the rail with the refill access portal
at the opposite end of the reservoir. See Figure 12 for illustration of applicator hous-
ing.
Figure 11: Precision Rail Vehicle Lubricating Applicator Location
Figure 12: Precision Rail Vehicle Lubricating Applicator (Front and Rear)
3. Insert the tip of the oil filled syringe into the refill hole on the applicator.
NOTE: On single array vehicles, if the applicator is located between the concentric
bearings (on the magnet array side of the vehicle), use the lubrication portal
that is shown in Figure 13 to access the oil refill hole on the applicator.
Applicator
Concentric
Bearings
Applicator
Eccentric
Bearings
Oil RefillFelt Applicator