Maintenance
Repair
80 MagneMotion
Rockwell Automation Publication MMI-UM037A-EN-P - April 2020
Install Pucks
1. Stop all motion on the section of the MagneMover LITE transport system where the
puck is being installed.
2. Remove the inside guide rail from a curve motor.
A. Remove the two screws that secure the V-braces to the guide rail.
B. Remove the two screws that secure the guide rail to the motor.
C. Lift the guide rail off the motor.
3. Install pucks and slide them onto the adjacent motors.
4. Replace the guide rail by reversing Step 2.
A. Apply Loctite 243 to the screws.
B. Tighten the guide rail mounting screw and the V-brace hardware to 3.4 N•m
[30 in•lb].
NOTE: The Loctite must cure for 2 hours at 22° C [72° F] before using the
transport system.
5. Return the MM LITE transport system to normal operation.