Maintenance
Repair
84 MagneMotion
Rockwell Automation Publication MMI-UM037A-EN-P - April 2020
Figure 22: Adhere Preload Spacer to Underside of Top Plate
8. Locate the plate assembly over the standoffs on the magnet assembly. Secure using
new M4 x 22 mm flat head screws and tighten to 1.5 N•m [13 in•lb].
The Loctite must cure for 2 hours at 22° C [72° F] before using the puck.
9. Replace the puck on the MM LITE transport system (see Replace Pucks on page 78).
Center Plate
Compliant Spacer
Glue Dot
Top P l ate