Maintenance
Repair
MagneMover LITE Service Manual 83
Rockwell Automation Publication MMI-UM037A-EN-P - April 2020
2. Place the puck on a non-metallic work surface with the magnet array down. Keep the
magnet array at least three feet away from metal objects and tools.
3. Remove the two screws that secure the puck top and center plates to the magnet
assembly. Lift the top and center plates off the magnet assembly as shown in Figure 21
and dispose of properly.
4. If there are O-rings on the threaded standoffs on the magnet assembly, remove the
O-rings and dispose of properly.
OPTIONAL
A. Remove the protective strip from the magnet assembly.
B. Use Isopropyl alcohol to clean the magnet assembly and remove any residue.
C. Place the new protective strip on a flat surface with the adhesive side up and
remove the adhesive protective backing from the strip.
NOTE: If a PTFE protective strip was used, it is replaced with the new
UHMW protective strip.
D. Carefully center the magnet array over the center of the adhesive strip. Fold
both ends of the strip over the sides of the array. Then fold the holes at each
end of the strip over the threaded standoffs as shown in Figure 21.
NOTE: Do not stretch the protective strip. Stretching reduces the life of the
adhesive, which causes the strip to peel away from the array.
E. Press the strip into place. Use a burnisher and make sure that there are no bub-
bles.
5. Remove the backing from the glue dot and apply the glue dot to the center surface of
the preload spacer as shown in Figure 22.
6. Locate the preload spacer on the center hole on the underside of the top plate, make
sure that the surface with the glue dot is fully seated and adhered to the top plate.
7. Align the top plate with the center plate and press together as shown in Figure 22.