MC16 Operating Manual 09.01.2020
23/52
ON/OFF
is available only for MC16-HRC controllers.
151
Grant Door Access with Normal
Lock Pulse (detailed)
Event
Access Point
When triggered then Access Door of the Access Point is opened for the time
specified by the parameter Lock Pulse. The function is usually used within
Login Options of the Access Point but it can also be assigned to input. In the
second case it is necessary to define Authentication Point and enable at least
single option in the area Authentication and Authorisation Options. Contrary
to function [175] when this function is used then separate event is generated
for each associated objects.
152
Grant Door Access with Extended
Lock Pulse (detailed)
Event
Access Point
When triggered then Access Door of the Access Point is opened for the time
specified by the parameter Lock Pulse Extended. The function is usually used
within Login Options of the Access Point but it can also be assigned to input.
In the second case it is necessary to define Authentication Point and enable
at least single option in the area Authentication and Authorisation Options.
Contrary to function [176] when this function is used then separate event is
generated for each associated objects.
153
Set Momentary T&A Mode
Event
Access Point
When triggered then Time&Attendance Mode is temporary selected at
Access Point. After user identification or when 8 s elapses, the default T&A
Mode is restored. Function parameter defines which T&A Mode is applied
when input is triggered.
154
Set Maintained T&A Mode
Event
Access Point
When triggered then Time&Attendance Mode is permanently selected at
Access Point. Function parameter defines which T&A Mode is applied when
input is triggered.
155
Register T&A Event
Event
Access Point
When triggered and followed by user identification then Time&Attendance
event is registered in the system. Function parameter defines which T&A
Mode is applied when input is triggered.
156
Set Authentication Policy
Event
Access Point
When triggered then Authentication Policy is selected at Access Point.
Function parameter defines which policy (e.g. Card and PIN) is applied when
input is triggered.
157
Call Elevator
Event
Access Point
When triggered then elevator is called. The function is available only for
MC16-EVK controllers.
158
Disable Door Access Toggle
Toggle
Access Point
As long as triggered then access granting at Access Point is disabled for all
users including Access Credentials with Master exemption.
159
Access Point Bell
Event
Access Point
When triggered then bell is activated at Access Point and output with the
function [64] is triggered.
161
Set Node ON Instantly
Event
Automation
When triggered then Automation Node is switched on without delay and