MC16 Operating Manual 09.01.2020
24/52
Node
indefinitely i.e. Default Time and Default Delay parameters of the node are
skipped.
162
Set Node ON with Default Time
Settings
Event
Automation
Node
When triggered then Automation Node is switched on according to Default
Time and Default Delay parameters of the node. The function is affected by
the option Activation Extending.
163
Set Node OFF Instantly
Event
Automation
Node
When triggered then Automation Node is switched off without any delay.
164
Set Alternately Node ON/OFF
Instantly
Event
Automation
Node
When triggered then Automation Node is switched to opposite state without
delay and indefinitely i.e. Default Time and Default Delay parameters of the
node are skipped.
165
Set Alternately Node ON/OFF
with Default Time Settings
Event
Automation
Node
When triggered then Automation Node is switched to opposite state
according to Default Time and Default Delay parameters of the node.
166
Set Node ON Toggle
Toggle
Automation
Node
As long as triggered then Automation Node remains switched on.
167
Set Node ON with Parametric
Time Settings
Event
Automation
Node
When triggered then Automation Node is switched on according to
Parametric Time and Parametric Delay parameters of the function. The
function is affected by the option Activation Extending.
168
Set Node OFF with Parametric
Time Settings
Event
Automation
Node
When triggered then Automation Node is switched off according to
Parametric Delay parameter of the function.
171
Register Guard Tour Event
Event
Access Point
When triggered then the event Guard Tour is recorded in the system and
output with the function [76] is activated.
172
Register Trace Event
Event
Access Point
When triggered then the event Trace is recorded in the system and output
with the function [77] is activated.
173
Register Muster Event
Event
Access Point
When triggered then the event Muster is recorded in the system and output
with the function [78] is activated.
174
Register Duress Event
Event
Access Point
When triggered then the event Duress is recorded in the system and output
with the function [79] is activated.
175
Grant Door Access with Normal
Lock Pulse
Event
Access Point
When triggered then Access Door of the Access Point is opened for the time
specified by the parameter Lock Pulse. The function is usually used within
Login Options of the Access Point but it can also be assigned to input. In the
second case it is necessary to define Authentication Point and enable at least
single option in the area Authentication and Authorisation Options. Contrary
to function [151] when this function is used then single event is generated for
all associated objects. The function is mainly used in case of elevators