MC16 Operating Manual 09.01.2020
indefinitely i.e. Default Time and Default Delay parameters of the node are
skipped.
Set Node ON with Default Time
Settings
When triggered then Automation Node is switched on according to Default
Time and Default Delay parameters of the node. The function is affected by
the option Activation Extending.
When triggered then Automation Node is switched off without any delay.
Set Alternately Node ON/OFF
Instantly
When triggered then Automation Node is switched to opposite state without
delay and indefinitely i.e. Default Time and Default Delay parameters of the
node are skipped.
Set Alternately Node ON/OFF
with Default Time Settings
When triggered then Automation Node is switched to opposite state
according to Default Time and Default Delay parameters of the node.
As long as triggered then Automation Node remains switched on.
Set Node ON with Parametric
Time Settings
When triggered then Automation Node is switched on according to
Parametric Time and Parametric Delay parameters of the function. The
function is affected by the option Activation Extending.
Set Node OFF with Parametric
Time Settings
When triggered then Automation Node is switched off according to
Parametric Delay parameter of the function.
Register Guard Tour Event
When triggered then the event Guard Tour is recorded in the system and
output with the function [76] is activated.
When triggered then the event Trace is recorded in the system and output
with the function [77] is activated.
When triggered then the event Muster is recorded in the system and output
with the function [78] is activated.
When triggered then the event Duress is recorded in the system and output
with the function [79] is activated.
Grant Door Access with Normal
Lock Pulse
When triggered then Access Door of the Access Point is opened for the time
specified by the parameter Lock Pulse. The function is usually used within
Login Options of the Access Point but it can also be assigned to input. In the
second case it is necessary to define Authentication Point and enable at least
single option in the area Authentication and Authorisation Options. Contrary
to function [151] when this function is used then single event is generated for
all associated objects. The function is mainly used in case of elevators