MC16 Operating Manual 09.01.2020
(MC16-EVC) and wired lockers (MC16-LCK).
Grant Door Access with Extended
Lock Pulse
When triggered then Access Door of the Access Point is opened for the time
specified by the parameter Lock Pulse Extended. The function is usually used
within Login Options of the Access Point but it can also be assigned to input.
In the second case it is necessary to define Authentication Point and enable
at least single option in the area Authentication and Authorisation Options.
Contrary to function [152] when this function is used then single event is
generated for all associated objects.
When triggered then Authorisation Mode is selected at Access Point.
Function parameter defines which mode is applied when input is triggered.
Set Default Authorisation Mode
When triggered then Default Authorisation mode is selected at Access Point.
Set Negative Authorisation Mode
When triggered then Negative Authorisation mode is selected at Access
Point.
Set Positive Authorisation Mode
When triggered then Positive Authorisation mode is selected at Access Point.
Set Normal Authorisation Mode
When triggered then Normal Authorisation mode is selected at Access Point.
Set External Authorisation Mode
When triggered then External Authorisation mode is selected at Access Point.
Set Delayed Authorisation Mode
When triggered then Delayed Authorisation mode is selected at Access Point.
Set Disabled Authorisation Mode
When triggered then Disabled Authorisation mode is selected at Access
Point.
Authorise Access for External
Authorisation Mode
When triggered then access is granted for External Authorisation mode
Reject Access for Delayed
Authorisation Mode
When triggered then access is denied for Delayed Authorisation mode.
Set Do Not Disturb Flag ON
When triggered then Do Not Disturb flag and outputs with functions [224],
[226] and [227] are switched on. The function is available only for MC16-HRC
controllers.
Set Do Not Disturb Flag OFF
When triggered then Do Not Disturb flag and output with function [227] are
switched off while outputs with functions [225] and [226] are switched on. The
function is available only for MC16-HRC controllers.
Set Alternately Do Not Disturb
Flag ON/OFF
When triggered then Do Not Disturb flag is switched to opposite state.
Outputs with functions [224], [225], [226] and [227] are switched accordingly.
The function is available only for MC16-HRC controllers.