Using the Markers R&S FSH
1309.6275.12 4.24 E-2
Marker menu
Marker
frequency
Delta marker
frequency
Delta marker
level
Marker
level
Delta marker
symbol
Marker
Marker
symbol
Delta marker
Controlling the marker:
Press the MARKER key.
The marker menu opens. If, as yet, no marker has
been activated, the main marker (MARKER) is turned
on automatically and placed on the maximum level in
the spectrum. The frequency and level at the point
indicated by the marker are displayed at the top of the
screen in the selected unit (= reference level unit). The
value entry box for the marker frequency opens.
The following actions can now be performed:
Change the marker position using the rotary knob
or the cursor keys.
Enter a marker position with the number keys and
terminate the entry with one of the unit keys.
Confirm the marker position by pressing the
ENTER key.
Controlling the delta marker:
Press the MARKER key.
Press the NEW MARKER softkey.
The R&S FSH turns on the delta marker and places it
on the second largest signal on the trace. The
frequency and level displayed at the top of the screen
are relative to the main marker, i.e. the R&S FSH
always outputs the frequency difference and the level
difference between the points marked by the main
marker and the delta marker. Simultaneously, the
value entry box for the delta marker frequency
difference is opened.
The following actions can now be performed:
Change the delta marker position with the rotary
knob or the cursor keys.