Applications
R&S
®
RTA4000
186User Manual 1335.7898.02 ─ 08
b) For a more detailed peak detection, enable the "Advanced Peak Setup".
Set the "Excursion", "Max. Width" and "Distance".
7. If necessary, set a reference marker:
a) Select the type of the "R-Marker".
b) If "R-Marker" = "Indicated", set the "Index".
c) If "R-Marker" ="Range", set the "Frequency" and "Span".
9.3.3.1 Marker menu
Access: "FFT" menu > enable "Peak List" > "Marker"
Source
Defines the waveform type that is searched for peaks.
Remote command:
SPECtrum:MARKer:SOURce on page 551
Peak Setup
See Chapter 9.3.3.2, "Peak setup", on page 186.
Min. Level
Defines the minimum absolute level for peak detection. See "Min. Level" on page 187.
R-Marker
See Chapter 9.3.3.3, "R-Marker settings", on page 188.
9.3.3.2 Peak setup
Access: "FFT" menu > enable "Peak List" > "Marker" > "Peak Setup"
The simple peak setup needs only the setting of the minimum level for peak detection.
More complex criteria can be defined in the advanced setup.