Remote control commands
R&S
®
RTA4000
484User Manual 1335.7898.02 ─ 08
REFCurve<m>:SOURce.................................................................................................484
REFCurve<m>:SOURce:CATalog?.................................................................................. 484
REFCurve<m>:STATe.....................................................................................................485
REFCurve<m>:UPDate.................................................................................................. 485
REFCurve<m>:SAVE..................................................................................................... 485
REFCurve<m>:LOAD.....................................................................................................485
REFCurve<m>:LOAD:STATe...........................................................................................486
REFCurve<m>:HORizontal:POSition................................................................................486
REFCurve<m>:HORizontal:SCALe..................................................................................486
REFCurve<m>:VERTical:POSition...................................................................................486
REFCurve<m>:VERTical:SCALe..................................................................................... 486
REFCurve<m>:WCOLor................................................................................................. 487
REFCurve<m>:LABel..................................................................................................... 487
REFCurve<m>:SOURce <Source>
Defines the source of the reference waveform.
Suffix:
<m>
.
1..4
Selects the reference waveform
Parameters:
<Source> CH1 | CH2 | CH3 | CH4 | MA1 | MA2 | MA3 | MA4 | MA5 | RE1 |
RE2 | RE3 | RE4 | D70 | D158 | SPEC | MINH | MAXH | AVER
CH1 | CH2 | CH3 | CH4 | MA1 | MA2 | MA3 | MA4 | MA5 | RE1 |
RE2 | RE3 | RE4
Any active channel, math, or reference waveform. CH3 and CH4
are only available with 4-channel R&S RTA4000 oscilloscopes.
D70 | D158
Logic probes, sources require MSO option R&S RTA-B1.
SPEC | MINH | MAXH | AVER
FFT waveforms: spectrum, min hold, max hold, average.
*RST:
CH1
REFCurve<m>:SOURce:CATalog?
Returns the source waveform.
Suffix:
<m>
.
1..4
Selects the reference waveform.
Parameters:
<Source Catalogue> CH1 | CH2 | CH3 | CH4 | QMA | RE1 | RE2 | RE3 | RE4 | D70 |
D158 | SPEC | MINH | MAXH | AVER
See REFCurve<m>:SOURce on page 484.
Usage: Query only