Remote control commands
R&S
®
RTE
1117User Manual 1326.1032.02 ─ 20
CHANnel<m>:BANDwidth............................................................................................. 1120
CHANnel<m>:CPLing...................................................................................................1120
CHANnel<m>:IMPedance............................................................................................. 1120
CHANnel<m>:OVERload.............................................................................................. 1121
CHANnel<m>:STATe <State>
Switches the channel signal on or off.
Suffix:
<m>
.
1..4
Selects the input channel.
Parameters:
<State> ON | OFF
*RST: OFF
Usage: Asynchronous command
CHANnel<m>:COUPling
<Value>
Selects the connection of the indicated channel signal.
Suffix:
<m>
.
1..4
Selects the input channel.
Parameters:
<Value> DC | DCLimit | AC
DC
Direct connection with 50 Ω termination, passes both DC and
AC components.
DCLimit
Direct connection with 1 MΩ termination, passes both DC and
AC components.
AC
Connection with 1 MΩ termination, removes DC and very low-
frequency components.
CHANnel<m>:GND <State>
Connects the signal to the ground.
Suffix:
<m>
.
1..4
Parameters:
<State> ON | OFF
*RST: OFF