TRIGger<m>:SPI:DPTO <DataPositionTo>
Defines the last bit or word of interest, if TRIGger<m>:SPI:DPOPerator is set to
INRange.
Parameters:
<DataPositionTo> Range: 1 to 4095 for triggering on one line (MISO or
MOSI), 2047 for triggering on both lines.
Increment: 1
*RST: 1
TRIGger<m>:SPI:FCONdition <DataOperator>
Selects the operator for the MISO and MOSI pattern.
Parameters:
<DataOperator> EQUal | NEQual
*RST: EQUal
TRIGger<m>:SPI:MISopattern <MISOPattern>
Specifies the pattern to be triggered on the MISO line.
Parameters:
<MISOPattern> Numeric or string pattern, see Chapter 18.4.6, "Bit pattern
parameter", on page 1076. The string parameter accepts the bit
value X (don't care).
Usage: Asynchronous command
TRIGger<m>:SPI:MOSipattern <MOSIPattern>
Specifies the pattern to be triggered on the MOSI line.
Parameters:
<MOSIPattern> Numeric or string pattern, see Chapter 18.4.6, "Bit pattern
parameter", on page 1076. The string parameter accepts the bit
value X (don't care).
Usage: Asynchronous command
18.17.4.3 SPI decode results
BUS<m>:SPI:FRAMe<n>:DATA?...................................................................................1466
BUS<m>:SPI:FCOunt?.................................................................................................1466
BUS<m>:SPI:FRAMe<n>:COUNt?................................................................................ 1466
BUS<m>:SPI:FRAMe<n>:BITRate?...............................................................................1466
BUS<m>:SPI:FRAMe<n>:STATus?................................................................................1467
BUS<m>:SPI:FRAMe<n>:STARt?..................................................................................1467
BUS<m>:SPI:FRAMe<n>:STOP?..................................................................................1468
BUS<m>:SPI:FRAMe<n>:WCOunt?.............................................................................. 1468