EasyManua.ls Logo

Rohde & Schwarz RTE1104 - Page 1757

Rohde & Schwarz RTE1104
2078 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTE
1757User Manual 1326.1032.02 ─ 20
Setting parameters:
<Frame>
<Field>
<Enabler> ON | OFF
Usage: Setting only
BUS<m>:CMSB:FILTer:FRAMe<n>:ENABle <Enable>
Enables or disables the specific frame to be filtered.
Suffix:
<m>
.
1..4
<n> *
Parameters:
<Enable> ON | OFF
*RST: OFF
BUS<m>:CMSB:FILTer:FRENable <Frame>, <Enabler>
Enables or disables the specific frame to be filtered.
Suffix:
<m>
.
1..4
Setting parameters:
<Frame>
<Enabler> ON | OFF
Usage: Setting only
BUS<m>:CMSB:FILTer:IMAX <Frame>, <Field>, <Data>
Sets the end value of an index range if BUS<m>:CMSB:FILTer:IOPerator is set to
INRange or RANGe.
Suffix:
<m>
.
1..4
Setting parameters:
<Frame>
<Field>
<Data>
Usage: Setting only
Protocols

Table of Contents

Related product manuals