Remote control commands
R&S
®
RTE
1882User Manual 1326.1032.02 ─ 20
Parameters:
<ErrorIBS> ON | OFF
*RST: ON
TRIGger<m>:CXPI:ERRor:IFS <ErrorIFS>
Triggers on an inter-frame-space (IFS) error, if TRIGger<m>:CXPI:TYPE is set to
ERRor.
Suffix:
<m>
.
1..3
Parameters:
<ErrorIFS> ON | OFF
*RST: ON
TRIGger<m>:CXPI:ERRor:LENGth
<ErrorLength>
Triggers on a length error, if TRIGger<m>:CXPI:TYPE is set to ERRor.
Suffix:
<m>
.
1..3
Parameters:
<ErrorLength> ON | OFF
*RST: ON
TRIGger<m>:CXPI:ERRor:PARity <ErrorParity>
Triggers on a parity error indicating a transmission error, if TRIGger<m>:CXPI:TYPE
is set to ERRor.
Suffix:
<m>
.
1..3
Parameters:
<ErrorParity> ON | OFF
*RST: ON
TRIGger<m>:CXPI:ERRor:UART <ErrorUart>
Triggers on an UART error, if TRIGger<m>:CXPI:TYPE is set to ERRor.
Suffix:
<m>
.
1..3
Parameters:
<ErrorUart> ON | OFF
*RST: ON