58
Jun. 2005
fig.update-5
9. After updating the “FACTORY RESET” is performed the automatically at
the time of the next startup.
Measures against system update
failure
If you fail in update, start the updating from beginning.
System Software Updating
Instructions (Updating to
Ver. 2.10 or Later)
Items Required
• Computer running Windows (floppy-disk drive required)
• System update file (version 1.10 or later)
• Floppy disks (2HD) x 7
Preparation
1. Format the floppy disks.
2. Download the system update file to the computer running Windows.
3. Double-click the downloaded file.
4. A window for specifying where to expand the data appears. Specify the
destination.
5. Seven folders are copied to the specified file-expansion destination.
6. Copy the data in each folder to the root directory of a floppy disk (one
folder to a disk).
Update Procedure
1. Insert the first update disk.
2. Hold down Rotary Sound [On/Off] and [Fast/Slow] and switch on the
power.
The updater is read in from the disk.
fig.update110-10.eps
3. Press [Composer Rec].
The screen shown below appears.
fig.update110-01.eps
4. Select the edition.
For 117-V specifications, press [Transpose +]. For other voltage
specifications, press [Transpose -].
One of the screens shown below appears, depending on the button
pressed.
117-V specifications
fig.update110-02.eps
100/230/240-V specifications
fig.update110-03.eps
* Pressing [Composer Reset] returns the display to the previous screen.
5. Press [Composer Rec].
One of the screens shown below appears, depending on the edition
selected.
117-V specifications
fig.update110-04.eps