Editing Function settings
42
r
V-Accordion FR-18 diatonic
The “Function” group also contains the following commands that apply to the FR-18 diatonic’s memory or a USB memory
you may have connected. These are explained on the indicated pages.
Selecting the desired function
1.
Press and hold the [SET] register (it flashes
slowly).
The Treble keyboard can now be used to select the
desired function. Please refer to the following illus-
tration for the treble buttons you need to press.
2.
Press the indicated treble button.
The [SET] register now flashes rapidly, and the Treble
keyboard can once again be used to play notes.
3.
Use treble registers [1]~[4] to select one of
the suggested values. Alternatively, use the
[DEC] or [INC] button to select the desired
value.
(Sometimes, there are more options than can be
selected with the 4 registers.)
You can also press and hold the [DEC]/[INC] buttons
to quickly select a significantly higher or lower value.
Each time you select a setting that is also assigned to
a treble register, the register in question lights. While
changing the setting with the [DEC]/[INC] buttons,
use the treble registers as a guide. You will notice
that one of the registers lights for each setting that
can also be selected by pressing a register.
NOTE
Press the [DRUMS/DEFAULT] to return to the last setting
you saved for the currently selected parameter.
4.
Press the [SET] register twice to leave the
FR-18 diatonic’s Function mode.
About the indications provided by the treble
registers
While the FR-18 diatonic’s four treble registers are used
to select some of the available “Function” settings, each
parameter usually provides more settings than there are
treble registers. Settings not directly available need to be
selected using the [DEC]/[INC] buttons.
That is why the FR-18 diatonic uses the following sys-
tem to provide at least a clue of the value you selected:
Button Function See
31 Load factory Set p. 51
32 USB driver p. 46
33 Import expansion sounds p. 39
34 Save User Program p. 37
35 Load User Programs p. 38
36 Import User Sets p. 38
37 Import Tablatures p. 39
1
2
5
6
9
10
3
4
15
16
13
14
7
8
11
19
20
23
24
17
18
21
22
25
26
12
27
30
31
34
35
28
29
32
33
36
37
1234
1234
1234
1234
The setting assigned to
register
[1]
is selected.
The setting assigned to
register
[2]
is selected.
The register lights. The register flashes. Off.
A smaller value than the setting assigned to
register
[1]
is selected.
A smaller value than the setting assigned to
register
[2]
is selected. (But it is more than the
setting assigned to
[1]
.)
FR-18d GB.book Page 42 Wednesday, December 15, 2010 1:54 PM