EasyManua.ls Logo

Roland XP-10 - Re-Transmitting the Saved Data Back to the XP-10 (Bulk Load); Pe Tarren Teer Meer; Set the Device ID Number and the System Exclusive Receive Switch; Re-Transmitting the Saved Data Back to the XP-10 Oo

Roland XP-10
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter
10.
Using
a
sequencer
or
computer
to
save
XP-10
settings
(Bulk
Dump)
Pc
a
Re-transmitting
the
saved
data
back
to
the
XP-10
(Bulk
Load)
Here’s
how
to
retransmit
the
data
(Exclusive
data)
that
was
saved
on
the
sequencer
back
to
the
XP-10.
This
operation
is
called
“Bulk
Load.”
When
you
execute
Bulk
Load,
the
contents
of
the
user
area
(the
location
where
data
that
you
create,
such
as
User
Tones,
is
stored)
may
be
lost,
depending
on
the
type
of
data
that
is
being
Bulk
Loaded.
For
example,
if
the
XP-10
receives
the
contents
of
a
“Drum
Dump
(User:
Drum),”
the
settings
of
the
20
User
Drum
Sets
will
be
lost.
If
you
wish
to
preserve
important
data,
use
“Bulk
Dump
(All)”
to
save
your
data
to
a
sequencer
etc.
After
saving
your
data,
you
can
use
the
following
procedure
to
load
the
data.
Connections
For
connecting
the
XP-10
to
a
sequencer,
refer
to
chapter
7
“Connections”
(p.43).
Using
a
MIDI
cable,
connect
the
XP-10's
MIDI
IN
to
the
sequencer's
MIDI
OUT.
For
connecting
the
XP-10
to
a
computer,
refer
to
chap-
ter
8
“Two
methods
of
connections”
(p.53).
If
you
are
using
MIDI
cables
to
make
connections,
connect
the
XP-10's
MIDI
IN
to
the
MIDI
OUT
of
the
MIDI
inter-
face
adapter/board.
Set
the
Device
ID
Number
and
the
System
Exclusive
Receive
Switch
Before
you
Bulk
Load
from
a
sequencer
etc.
into
the
XP-10,
you
need
to
make
“Device
ID
Number”
and
“System
Exclusive
Receive
Switch”
settings
using
the
following
procedure.
1.
Press
[EDIT].
The
indicator
will
light.
2.
Use
VALUE[-]/[+]
to
select
“System
Setup”
and
press
[ENTER].
3.
Press
[7]
several
times
to
select
“Device
ID#.”
*
If
you
hold
down
[ENTER]
while
you
press
[7],
you
will
return
to
the
previous
item.
4.
Use
VALUE[-]/[+]
to
set
the
Device
ID
Number
to
the
same
setting
as
when
you
executed
Bulk
Dump.
5.
Press
[7]
several
times
to
select
“Rx
System
Excl.”
6.
Use
VALUE[-]/[+]
to
turn
the
setting
“ON.”
7.
Press
[EDIT].
The
indicator
will
go
off,
and
the
previous
display
will
reappear.
58
Re-transmitting
the
saved
data
back
to
the
XP-10
When
you
have
finished
making
settings,
play
back
the
sequencer
etc.
to
re-transmit
the
data
back
to
the
XP-10.
Be
sure
to
play
back
the
sequencer
at
the
same
tempo
that
was
used
when
the
data
was
recorded.
If
the
tempo
is
different,
the
XP-10
may
not
receive
the
data
correctly.

Table of Contents

Other manuals for Roland XP-10

Related product manuals