82 • DashBoard Interface Overview RCP-ME User Guide (v4.0)
Configuration Options
Newly assigned IP addresses and netmasks are checked for valid values before being applied to an RCP-ME. If
the new values are invalid they will be discarded silently. Only a refresh of the RCP-ME Connection Editor will
show that the values were not set.
The bottom half of the RCP-ME Connection Editor is organized into three areas: Network Settings, Servers to
Connect to, and Connections. A toolbar at the bottom of the RCP-ME Connection Editor provides buttons for
updating the panel.
Network Settings Area
Table 16.2 summarizes the options for specifying the network settings for the RCP-ME.
Servers to Connect to Area
Table 16.3 summarizes the options for configuring communications between the RCP-ME and a server.
Details <text> Assigned by the user to give an RCP-ME specific
details. For example, a physical location or a brief
description of its use.
This field has a maximum of 16 characters and is
used for description and identification only.
MAC Address
(read-only)
# The Media Access Control address (MAC address)
is the unique hardware address for the RCP-ME on
a network. This parameter is not user configurable
Name <text> This field can be assigned by the user to uniquely
name an RCP-ME.
This field has a maximum of 16 characters and is
used for description and identification only. The
DashBoard tree view uses the text in this field as
the device tree name.
Group # A group number can be assigned by the user to
organize devices into groups. For example, users
can assign separate group numbers for devices in
different physical areas.
This field has a maximum of 10 characters and by
default is blank.
Table 16.2 Network Settings Area
Item Parameters Description
IP Address #.#.#.# Enter or edit the IP address of the device
Netmask #.#.#.# Enter or edit the IP netmask of the device
Gateway #.#.#.# Enter or edit the IP gateway of the device
TCP Port # Enter or select the Transmission Control Protocol
port number used for network communication. By
default, the TCP Port is 5000, and any client
devices/apps should be setup with the same port
number
Table 16.1 Device Details Area
Item Parameters Description