Controller Functionality
AYC-Qx4 family manual Page 36
Entering Programming Mode
1) Press the # key twice within
2 seconds.
Mode LED will turn off.
Door LED will turn red.
2) Enter your Programming Code
Door LED will turn green
and the AYC-Qx4 will be
in Programming Mode.
Note:
The AYC-Qx4 must be in Normal Mode to enter the
Programming mode.
The factory four-digit Programming Code is 1234.
If a Programming Code is not entered within five seconds, the
AYC-Qx4 will return to Normal mode.
Exiting Programming Mode
1) Press the “#” key two times within 2 seconds
You will hear 3 beeps.
The Door LED will turn off
and the Mode LED will return to Normal.
2) Wrong entries may reset the controller back to Normal
mode.
3) While in Programming mode, if no key is pressed for one
minute the AYC-Qx4 will
exit Programming mode
and return to Normal mode.
Changing Lock Strike Code
The Lock Strike Code is mainly used as a method to quickly test
the Lock Strike Relay during installation.
? ? ? ?
Mode/Transmit
Door/Program
Red
Mode/Transmit
Door/Program
Green
Mode/Transmit
Door/Program
Green
Mode/Transmit
Door/Program
Green

Table of Contents

Other manuals for Rosslare AYC-Q64B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosslare AYC-Q64B and is the answer not in the manual?

Rosslare AYC-Q64B Specifications

General IconGeneral
BrandRosslare
ModelAYC-Q64B
CategoryController
LanguageEnglish

Related product manuals