M
230V
60Hz
1 Ø
Black
Green
White
Overhead
Limit Switch
Up
Switch
White
Black
Black
erhead Switch
Voltage: 277V
Current: 25A
Connect supply to wires in box as
per Fig. 16. Attach ground wire to
screws provided.
Attach ground wire here.
208-230V 60Hz
Single Phase
Attach black wire
to one motor wire.
wire to one
motor wire.
Black
Green
Fig. 15
Single Phase Power Unit
MOTOR OPERATING DATA TABLE - SINGLE PHASE
LINE VOLTAGE RUNNING MOTOR VOLTAGE RANGE
208-230V 50Hz. 197-253V
208-230V 60Hz. 197-253V
Note: 60Hz. Single phase motor CAN NOT be run on 50Hz. line
without a physical change in the motor.
13. Electrical: Have a certified electrician run
appropriate power supply to motor, Fig. 15 & 16.
Size wire for 20 amp circuit. For single phase
4HP motor wire for 30 amp circuit. See Motor
Operating Data Table.
Never operate the motor on line
voltage less than 208V. Motor damage may occur.
IMPORTANT: Use separate circuit for each power
unit. Protect each circuit with time delay fuse or
circuit breaker. For single phase 208-230V, use 20
amp fuse. For single phase 4HP motor use 30 amp
fuse. Three phase 208-240V, use 20 amp fuse. For
three phase 400V and above, use 10 amp fuse. For
wiring see Fig. 15, Fig. 16, and Fig.16b. All wiring
must comply with NEC and all local electrical
codes.
Note: 60Hz. single phase motor CAN NOT be run
on 50Hz. line without a physical change in the
motor.
NOTE: Assure cord used for connection
between the overhead switch and power
unit is of the type specified in:
UL201, Sections 10.1.1.3 & 10.1.1.4
(Example: SO, G, STO) Size for 25 amp
circuit. See UL 201, Section 15 for proper