INSTALLATION MANUAL
AIRCRAFT ENGINES
page 18 - 8
Initial issue, May 01/99
Effectivity: 447 UL SCDI, 503 UL DCDI, 582 UL DCDI /mod. 99
d00328
Battery:
To ensure reliable starting, a battery of least 16 Ah (high-
discharge battery) must be utilized. A higher battery amp-
hour-rate would be preferable. Cables supplying power to the
starter from the battery and to ground should be a minimum 10
mm
2
flexible multi-strand cable.
Power source:
from rectifier regulator
Starter relay (992 819)
Starter control should be via starter relay (supplied with starter
kit) wired as shown above.
Fuse
A 16 Amp fuse must be installed between battery charging
circuit and main power terminal.