d07068.fm
SI-912 i-029 / SI-915 i-012
SI-916 i-007
SERVICE INSTRUCTION
08 February 2024 74-20-00
Initial Issue Page 7 of 15
Copyright - BRP-Rotax GmbH & Co KG. All rights reserved.
3.5.1) Double ignition coil - removal
1 Allen screw
2 Washer
3 Cable clamp
Fig. 2
Step Procedure
1 Disconnect the negative terminal of the battery.
2 Remove the cable clamps with Allen screws and lock washers from the intake mani-
fold, if necessary.
Step Procedure
3 Cut the cable tie from the exhaust gas temperature sensor cable (cyl. 1_3) connected
with the double ignition coil cable.
m
WARNUNG
NOTICE
Do not damage the cables. Always cut cable ties on the side of the support
plate facing away from the cables.