d06703.fm
SI-912 i-024
SI-915 i-006
SERVICE INSTRUCTION
03 July 2019 76-10-00
Initial Issue Page 11 of 18
Copyright - BRP-Rotax GmbH & Co KG. All rights reserved.
3.3.2) Replacement of female connector (Stator side)
In order to preserve maximum wire length, remove the wires with crimped female pins from Stator
B connector housing (gray).
Fig. 10
Fig. 11
Step Procedure
1
Label each of the 3 yellow wires with its location within the connector. The rear of the
connector housing is marked with numbers (1).
2 Gently pry the rectangular rubber seal (2) from the rear of the connector.
Step Procedure
3 Using fine-nosed pliers, pull the retaining wedge (3) from the connector housing.
4
Remove pins from connector housing by releasing plastic retaining tabs (4) and pull-
ing wires from behind.
Step Procedure
5 Cut each wire at crimped pins (5).
6
Ensure that wires are still clearly numbered and pull rectangular rubber seal (6) from
the wires.
1 Connector housing
with numbers
2 Rubber seal
3 Retaining wedge
4 Retaining tab